Building Optical Glass Series Testing Equipment
1、Product introduction
Mainly used for building safety glass (toughened, laminated glass, fire glass) impact test.
2、standard of execution
GB 15763.3-2009
GB/T9963-1998
3、sample requirements
Glass of the same kind of original plate glass of the same thickness as the product, and the size of which is approximately 610mm×610mm, manufactured under the same technological conditions as the product (or cut from the product).
4、Main technical parameters
Drop height: 1m~5m;
Dimensions: length 1.2× width 0.66× height 5.6m
Steel ball mass: 1040g±10g (diameter: 63.5mm), 2260g ±20g (diameter: 82.5mm)