Testing equipment for curtain wall doors
1、Product introduction
Perform physical performance tests on building curtain walls, including air tight, water tight, wind tight, in-plane deformation performance tests.
2、standard of execution
GB/T 15227-2007 Test method of air permeability, watertightness, wind load resistance performance for curtain walls.GB/T 18250-2015 Graduations and test methods for performance between stories of curtain wall.
GB/T 21086-2007 Curtain wall for building.
AS/NZS 4284-2008 esting of Building Facades.
AAMA 501.1-2005 Standard Test Method For Water Penetration Of Windows,Curtain Walls And Doors Using Dynamic Pressure.
ASTM E283-2004 Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen.
ASTM E330-2002 Test Method for Structural Performance of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference.
ASTM E331-2000 Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference.
ASTM E547-2000(2009) Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Cyclic Static Air Pressure Difference.
BS EN 12152-2002 Curtain walling - Air permeability - Performance requirements and classification.
BS EN 12153-2000 Curtain walling Air permeability Test method.
BS EN 12154-2000 curtain walling watertightness performance requirements and classification.
BS EN 12155-2000 Curtain walling Watertightness Laboratory test under static pressure.
BS EN 12179-2000 curtain walling resistance to wind load test method.
BS EN 13050-2011 curtain walling watertightness laboratory test under dynamic condition of air pressure and water spray.
3、Main technical parameters
name
main indicators
precision
Maximum static pressure differential of pressure box
±10 kPa
dynamic wind pressure fluctuates
pressure:2500Pa
cycle:3~5s
pressure:±2%
Air flow
0~565m3/h
<3%
spray range
0~4 L/(m2·min)
Deformation detection
displacement:0~100mm
pressure:>±5000Pa
displacement:≤0.1mm
pressure:≤1%
Interlayer deformation
deformation value:±1/100
cycle:3~10s
Displacement:≤0.5%FS
4、model
model
Max test specification
(W×H)
required space(l×W×H)
MQD3045
3m×4.5m
8m×8m×7m
MQD4060
4m×6m
8m×8m×8m
MQD5080
5m×8m
11m×10m×12m
MQD6090
6m×9m
13m×13m×14m
MQD5011
5m×11m
12m×10m×15m
MQD80120
8m×12m
14m×15m×17m
MQD100120
10m×12m
17m×15m×17m