MQD Building curtain wall physical performance testing equipment
Product introduction
Building curtain wall physical performance test, including airtight, watertight, wind pressure resistance, in-plane deformation performance test.
Detailed Introduction

1、Product introduction

Perform physical performance tests on building curtain walls, including air tight, water tight, wind tight, in-plane deformation performance tests.

2、standard of execution

GB/T 15227-2007 Test method of air permeability, watertightness, wind load resistance performance for curtain walls.

GB/T 18250-2015 Graduations and test methods for performance between stories of  curtain wall.

GB/T 21086-2007 Curtain wall for building.

AS/NZS 4284-2008 esting of Building Facades.

AAMA 501.1-2005 Standard Test Method For Water Penetration Of Windows,Curtain Walls And Doors Using Dynamic Pressure.

ASTM E283-2004 Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen.

ASTM E330-2002 Test Method for Structural Performance of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference.

ASTM E331-2000 Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference.

ASTM E547-2000(2009) Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Cyclic Static Air Pressure Difference.

BS EN 12152-2002 Curtain walling - Air permeability - Performance requirements and classification.

BS EN 12153-2000 Curtain walling  Air permeability  Test method.

BS EN 12154-2000 curtain walling watertightness performance requirements and classification.

BS EN 12155-2000 Curtain walling  Watertightness Laboratory test under static pressure.

BS EN 12179-2000 curtain walling resistance to wind load test method.

BS EN 13050-2011 curtain walling watertightness laboratory test under dynamic condition of air pressure and water spray.


3、Main technical parameters

name

main indicators

precision

Maximum static pressure differential of pressure box

±10 kPa

dynamic wind pressure fluctuates

pressure2500Pa

cycle:3~5s

pressure:±2%

Air flow

0~565m3/h

<3%

spray range


0~4 L/(m2·min)

Deformation detection

displacement:0~100mm

pressure:>±5000Pa

displacement:≤0.1mm

pressure:≤1%

Interlayer deformation

deformation value:±1/100

cycle:3~10s

Displacement:≤0.5%FS















4model

model

Max test specification

(W×H)

required space(l×W×H)

MQD3045

3m×4.5m

8m×8m×7m

MQD4060

4m×6m

8m×8m×8m

MQD5080

5m×8m

11m×10m×12m

MQD6090

6m×9m

13m×13m×14m

MQD5011

5m×11m

12m×10m×15m

MQD80120

8m×12m

14m×15m×17m

MQD100120

10m×12m

17m×15m×17m