Testing equipment for curtain wall doors
1、standard of execution
GB/T 7106-2008 Graduations and test methods of air permeability, watertightness, wind load resistance performance for building external windows and doors.
BS EN 1026-2000 Windows and doors Air permeability Test method.
BS EN 1027-2000 Windows and doors watertightness Test method.
BS EN 12211-2000 Windows and doors Resistance to wind load Test method.
2、Main technical parameters
name |
main indicators |
precision |
||
Wind pressure resistance
|
Static pressure difference:≥±5000Pa displacement:0~50mm |
Static pressure difference:≤2% displacement:≤±0.1mm |
||
Air tightness |
Air flow:0~300m3/h |
Air flow:≤3% Static pressure difference:≤2% |
||
Water tightness
|
Stable pressure |
spray range:2 L/(m2·min) Static pressure difference:≥700 Pa |
spray range:2L/(m2·min) Static pressure difference:≤2% |
|
Pressure fluctuations |
spray range:2~3L/(m2·min) cycle:≥3s |
spray range:3L/(m2·min) cycle:2s~6s Pressure fluctuations:≤2%cycle:3s~5s |
||
Power supply |
Three phase five wire system:AC380V 15kW |
Water requirement:Up and down water |
3、model
model
|
Max size of test piece(m) |
Static pressure box size(m) |
Fan size(m) |
Minimum size of the room(m) |
MCD2424 |
2.4×2.4 |
L2.7×W1.4×H3 |
2.5×2.5×2 |
5×4×3.5 |
MCD3030 |
3.0×3.0 |
L3.5×W1.4×H3.6 |
2.5×2.5×2 |
6×4×4 |
MCD3535 |
3.5×3.5 |
L4×W1.4×H4.1 |
2.5×2.5×2 |
7×4×4.5 |
MCD3550 |
5.0×3.5 |
L5.5×W2.9×H4.1 |
2.5×2.5×2 |
8.5×4×4.5 |